300ABH-300 family · An Abhilekh Product

ABH-300-AI

Universal analog input monitor

4–20 mA · 0–10 V

Four universal analog channels (ADS1115) for transmitters, PLCs and process signals — pressure, flow, humidity, level — beside the standard channels.

ABH-30011 channelsIP65E-paper 200×200Wi-Fi 2.4 GHz (ESP32-C3-MINI-1U)
ABHILEKH12.4 mAAI ×4ABHILEKH · NEODRICS

Design visualization · 106.4 × 150.0 × 29.3 mm

NormalExcursionFault
11
Sensing channels
409,600
Readings stored
≈76 d USB-loss backup
Battery life (calc.)
IP65
Ingress protection
1 s minimum
Default interval
Specifications

ABH-300-AI — every number a QA team asks for

Channel-level accuracy, memory depth in readings, enclosure geometry and the firmware trust chain — the full picture before you ask for the pilot.

ABH-300-AI · published specifications
Product typeIndustrial · Wi-Fi monitor
Sensing channels11 (4 × universal analog · Ambient T + RH + pressure · 4 × probe temperature)
4 × universal analogExp-E (ADS1115, 16-bit) · 4–20 mA / 0–10 V / 0–5 V loop-powered
Ambient T + RH + pressureSHT41 + BMP390 on-board
4 × probe temperaturePT100 Class A via probe board (optional)
Measurement accuracyProbe element ±0.15 °C at 0 °C (PT100 Class A, IEC 60751) · channel ±0.62 °C uncalibrated → ±0.36 °C after 4-point factory calibration
Display & indication1.54″ e-paper 200 × 200 · −25…+50 °C · holds last reading while asleep
ConnectivityWi-Fi 2.4 GHz (ESP32-C3-MINI-1U) · MQTT over TLS 1.2+ — Internal FPC · ≤2 dBi
PowerUSB 5 V + Molicel P28A 18650 pack
Battery life≈76 d USB-loss backup (calculated, spec-compliant logging at firmware defaults; ≈46 d at −20 °C) — ≈76 d USB-loss backup (calculated)
Memory16 MB W25Q128JV · 409,600 readings · separate never-erased audit region
Sample interval1 s minimum · configurable
Enclosure106.4 × 150.0 × 29.3 mm · PC/ABS · UL94 V-0 · UV-stabilised · RAL 7035 grey
Ingress protectionIP65 (design target)
MountingKeyhole (2×) + bonded magnets · M12 cable ports
Operating band−25 to +50 °C (e-paper limit)
FirmwareSigned .abhfw packages · dual-bank A/B · RSA-2048 · trial boot with automatic rollback · MQTT over TLS 1.2+ with per-device credentials · X.509 client certificates / mTLS on the roadmap
Factory identityABH-[model]-[YYWW]-[5-digit sequence] — factory identity written to the ID EEPROM
PortsAnalog terminal entries (Exp-E) · USB-C

The ABH line is at the design-frozen, pre-production stage: every enclosure has passed generated fit-check geometry (791/791 checks, 20/20 SKUs) and every battery-life, drop, thermal and IP figure shown is a calculated or simulated design estimate — measured values replace them as validation hardware runs. Regulatory marks above are the certification roadmap, not held certificates.

Why it fits
  • Bring existing transmitters into the compliance record before they retire
  • Loop-powered 4–20 mA inputs — no extra PSU rail at the instrument
  • Same alerting, reporting and audit chain as native sensor channels
Built for
  • Process signals — 4–20 mA / 0–10 VUniversal analog inputs bring tanks, humidity transmitters and PLC signals into the same record.
See all applications
Works with
  • PRB-PT100-3W — PT100 immersion probePRB-PT100-3W-3M · PRB-PT100-3W-5M · PRB-PT100-3W-10M
Downloads

Datasheets describe the current design release (ABH-PLATFORM 0.0.4). Battery-life and IP figures inside are calculated design estimates; measured values follow validation hardware.

Part of the platform

One PCB, one firmware, one compliant record

One 80 × 50 mm 4-layer platform PCB — 146 parts, single-sided SMT — becomes 20 SKUs by BOM selection and a SKU record in the on-board ID EEPROM.

Signed firmware

Signed .abhfw packages · dual-bank A/B · RSA-2048 · trial boot with automatic rollback

Data integrity

MQTT over TLS 1.2+ with per-device credentials · X.509 client certificates / mTLS on the roadmap

Offline evidence

Plug an offline logger into a PC and it enumerates a FAT16 drive with README.TXT, DATA.CSV and an ECDSA P-256-signed REPORT.PDF — a self-verifying trip record.

Calibration

Probe channel templates live in the ID EEPROM; the platform tracks NIST-traceable calibration certificates, due dates and reminders per probe.

Certification roadmap: EN 12830:2018 — temperature recorders · CE — RED / EMC / safety · FCC Part 15 · WHO PQS E006 — vaccine cold chain · IEC 61010-1 / IEC 62368-1 · UN 38.3 / IEC 62133-2 — cells & packs — targets, not held certificates.

Evaluate on your cold chain

Put the ABH-300-AI to work

Book a demo and we'll scope a pilot around your sites — quantities, probes, alert rules and the reports your QA team will hand the inspector.