100ABH-100 family · An Abhilekh Product

ABH-100-D

Dry-ice & ULT logger

ULT, logger outside

For ULT freezers and dry-ice shipper monitoring: the logger stays in ambient, a Class-A PT100 probe on a 3 m cable measures the cold.

ABH-1003 channelsIP65LED indicationOffline — no radio
ABH-100-D−79.8 °CABHILEKH · NEODRICS

Design visualization · 88.2 × 69.9 × 28.3 mm · probe pod 38.5 mm

NormalExcursionFault
3
Sensing channels
409,600
Readings stored
≈4.6 yr
Battery life (calc.)
IP65
Ingress protection
300 s default
Default interval
Specifications

ABH-100-D — every number a QA team asks for

Channel-level accuracy, memory depth in readings, enclosure geometry and the firmware trust chain — the full picture before you ask for the pilot.

ABH-100-D · published specifications
Product typeOffline · probe logger
Sensing channels3 (Probe temperature · Ambient T + RH)
Probe temperaturePRB-PT100-3W Class A · −50…+200 °C · ±0.15 °C at 0 °C
Ambient T + RHSHT41 (logger lives outside the freezer)
Measurement accuracyProbe element ±0.15 °C at 0 °C (PT100 Class A, IEC 60751) · channel ±0.62 °C uncalibrated → ±0.36 °C after 4-point factory calibration
Display & indicationLED status indicator (single red LED, blink codes: heartbeat flash = OK · fast blink = excursion · solid = fault)
ConnectivityOffline — no radio
PowerER14505M AA Li-SOCl₂ 3.6 V · 2.0 Ah
Battery life≈4.6 yr (calculated, spec-compliant logging at firmware defaults; ≈3.3 yr worst-case) — MAX31865 RTD front-end needs ≥3.0 V — 3.6 V cell behind the buck
Memory16 MB W25Q128JV · 409,600 readings · separate never-erased audit region
Sample interval300 s default · 1 s minimum
Enclosure88.2 × 69.9 × 28.3 mm · probe pod 38.5 mm · Healthcare-grade disinfectant-resistant PC/ABS · UL94 V-0 · white
Ingress protectionIP65 (design target)
MountingKeyhole (2×) + bonded 10×2 mm magnets · M12 probe port in pod
Operating band−40 to +70 °C (logger) · probe to −50 °C
FirmwareSigned .abhfw packages · dual-bank A/B · RSA-2048 · trial boot with automatic rollback · MQTT over TLS 1.2+ with per-device credentials · X.509 client certificates / mTLS on the roadmap
Factory identityABH-[model]-[YYWW]-[5-digit sequence] — factory identity written to the ID EEPROM
Probe portM12 A-coded on the probe pod (J8)
Local indicationLED status indicator (single red LED, blink codes: heartbeat flash = OK · fast blink = excursion · solid = fault)

The ABH line is at the design-frozen, pre-production stage: every enclosure has passed generated fit-check geometry (791/791 checks, 20/20 SKUs) and every battery-life, drop, thermal and IP figure shown is a calculated or simulated design estimate — measured values replace them as validation hardware runs. Regulatory marks above are the certification roadmap, not held certificates.

Why it fits
  • Class-A PT100 accuracy at −80 °C — where NIST-traceable evidence actually gets questioned
  • Logger stays at ambient: cells and display stay in their comfort zone
  • Phenyl-silicone gasket option when the logger itself rides dry ice
Built for
  • ULT freezers & dry iceLogger stays outside the freezer; a Class-A PT100 probe measures inside — accuracy where it matters.
See all applications
Works with
  • PRB-PT100-3W — PT100 immersion probePRB-PT100-3W-3M · PRB-PT100-3W-5M · PRB-PT100-3W-10M
  • ABH-300 — Industrial multi-probe monitor
Downloads

Datasheets describe the current design release (ABH-PLATFORM 0.0.4). Battery-life and IP figures inside are calculated design estimates; measured values follow validation hardware.

Part of the platform

One PCB, one firmware, one compliant record

One 80 × 50 mm 4-layer platform PCB — 146 parts, single-sided SMT — becomes 20 SKUs by BOM selection and a SKU record in the on-board ID EEPROM.

Signed firmware

Signed .abhfw packages · dual-bank A/B · RSA-2048 · trial boot with automatic rollback

Data integrity

MQTT over TLS 1.2+ with per-device credentials · X.509 client certificates / mTLS on the roadmap

Offline evidence

Plug an offline logger into a PC and it enumerates a FAT16 drive with README.TXT, DATA.CSV and an ECDSA P-256-signed REPORT.PDF — a self-verifying trip record.

Calibration

Probe channel templates live in the ID EEPROM; the platform tracks NIST-traceable calibration certificates, due dates and reminders per probe.

Certification roadmap: EN 12830:2018 — temperature recorders · CE — RED / EMC / safety · FCC Part 15 · WHO PQS E006 — vaccine cold chain · IEC 61010-1 / IEC 62368-1 · UN 38.3 / IEC 62133-2 — cells & packs — targets, not held certificates.

Evaluate on your cold chain

Put the ABH-100-D to work

Book a demo and we'll scope a pilot around your sites — quantities, probes, alert rules and the reports your QA team will hand the inspector.